APIN_Zastita servera.cdr

Слични документи
PowerPoint-Präsentation

OBAVIJEST O PRVOJ IZMJENI DOKUMENTACIJE Naziv Naručitelja: GENERA d.d., Kalinovica, Svetonedeljska cesta 2, Rakov Potok Naziv projekta: Izgradn

ISPITIVANJE DISTRIBUTIVNIH PLINOVODA I KUĆNIH PRIKLJUČAKA

Sonniger katalog_2017_HR_ indd

Projektantske podloge Kondenzacijski uređaji Tehnički list ecotec plus 48/65 kw Grijanje Hlađenje Nove energije

Dan Datum Od - do Tema Predavači Broj sati MODUL 1 ZAGREB, Ukupno sati po danu poned ,30-11,40 (s pauzom od 30 min) 5.

CJENIK KUĆNE I KOMERCIJALNE SERIJE AZURI DC INVERTER ZIDNI KLIMA UREĐAJI SUPRA STANDARDNO UKLJUČENO -- Wifi sučelje -- Led display -- Automatski rad -

Microsoft PowerPoint - Sustav_upravljanja_energetikom_objekta_V1

Stručno usavršavanje

"FITIŠ-JU"d.o.o PP Centrala serije KFP-CF Datum:28/10/09 "FITIŠ - JU" d.o.o Tema: Kratko uputsvo za rukovanje Šifra: List:1 Konvencionalna centrala za

Vaillant BiH 2017 cjenik final web.pdf

Microsoft Word - V03-Prelijevanje.doc

Narodne novine, broj 8/06. Napomena: Objavljeno u Narodnim novinama br. 8/06. na temelju članka 53. stavka 2. Zakona o zaštiti od požara (Narodne novi

INDIKATOR SVJETLA FUNKCIJE TIPKI 1. Prikazuje se temperatura i parametri upravljanja 2. Crveno svjetlo svijetli kad grijalica grije 3. Indikator zelen

VISOKO UČINKOVITE TOPLINSKE PUMPE ZRAK/VODA S AKSIJALNIM VENTILATORIMA I SCROLL KOMPRESOROM Stardandne verzije u 10 veličina Snaga grijanja (Z7;V45) 6

Kanalni ventilatori Kanalni ventilatori za sustave komforne ventilacije Širok raspon protoka: 400 do m³/h Lakirano kućište u standardnoj izvedb

Microsoft Word - privitak prijedloga odluke

Na temelju članka 118. Zakona o odgoju i obrazovanju u osnovnoj i srednjoj školi (Narodne novine, 87/08., 86/09., 92/10.,105/10,90/11., 5/12, 16,12,86

1 Poštovani korisniče, Oksimetar Zahvaljujemo se na kupovini Comdek MD-651P e-angel pulsnog oksimetra. Ovo uputstvo će Vam obezbediti sve potrebne inf

Untitled-1.cdr

Učinkovitost dizalica topline zrak – voda i njihova primjena

REBALANS PLANA NABAVE ZA GODINU IMUNOLOŠKI ZAVOD REDN I BROJ EVIDENCIJSKI BROJ NABAVE NAZIV PREDMETA NABAVE OCIJENJENA VRIJEDNOST NABAVE BEZ PDV

untitled

Z-15-68

Na temelju članka 45. stavka 5. Zakona o zaštiti na radu (»Narodne novine«, broj 71/14, 118/14 i 154/14), ministar nadležan za rad uz suglasnost minis

Rittal IT infrastructure - Next level for data centre

EK Fleet - Sustav za satelitsko praćenje vozila

Radovi u skučenim prostorima radovi u spremnicima Alexander Leitner, dipl. ing. Stručno tijelo za kemiju Opća ustanova za osiguranje od nesreće na rad

Installation manuals

Klimaoprema katalog PPZEN

R E P U B L I K A H R V A T S K A

Laboratorij za analitiku i toksikologiju d.o.o. Laboratory for Analytics and Toxicology Ltd. OIB: Matični broj: IBAN: HR

Simboli za tehnicke seme JUS U.J1.220

10.4-A4-S

Weishaupt monarch (WM) serija

voith.com Energetski učinkoviti na svim cestama Zračni kompresori

1. BP LED SIJALICA E27 BP LED Sijalica je tip štedne sijalice (SSL) koja koristi diode koje emitiraju svijetlost (LEDs) kao izvor svijetlosti. Te diod

Hrvatske autoceste održavanje i naplata cestarine d.o.o., Koturaška cesta 43, Zagreb, Hrvatska / tel.: / fax.: Društvo

Zagreb, 3. veljače 2017.

Microsoft PowerPoint - Prskalo - prezentacija 2015.ppt [Način kompatibilnosti]

Pumping Smart Card

PROTIVPROVALA JUN HONEYWELL.xlsx

Lučka uprava Ploče 1. IZMJENE GODIŠNJEG PROGRAMA RADA I RAZVOJA LUKE SA FINANCIJSKIM PLANOM LUČKE UPRAVE PLOČE ZA GODINU Listopad

Narodne novine ; broj 29/13. i 87/15. Napomena: Objavljeno Narodnim novinama br. 29/13. i 87/15. na temelju članka 26. stavka 1. Zakona o zaštiti od p

Pravilnik o priključenju spremnika energije na elektroenergetski sustav Zlatko Ofak (HOPS), Alan Župan (HOPS), Tomislav Plavšić (HOPS), Zora Luburić (

Untitled-1.cdr

42000 Varaždin, Vladimira Nazora 12 Tel/fax: 042/ IBAN: HR OIB: PRILOZI UZ ZAHTJE

VIESMANN VITODENS 222-W Informacijski list Br. narudž. i cijene: vidi cjenik VITODENS 222-W Tip B2LA Kompaktni plinski kondenzacijski uređaj, 3,2 do 3

Planiranje primjene i ugradnji AUTAP sustava 1. Planiranje primjene Kod planiranja primjene AUTAP sustava prvo treba odlučiti da li je pogodna/poželjn

PRILOG I. PONUDBENI LIST S DODACIMA ZA ZAJEDNICU PONUDITELJA I PODIZVODITELJE / APPENDIX I. BIDDING LIST WITH APPENDICES FOR JOINT BIDDERS AND SUB- CO

caprari-elektrane_Layout 1.qxd

Mjerna oprema 2011

Kontrolna lista za obilazak radnog mjesta Doktor medicine u bolnici KONTROLNA LISTA ZA OBILAZAK RADNOG MJESTA Svrha obilaska radnog mjesta je utvrditi

Tehničko rešenje: Industrijski prototip dvostrukog trofaznog analizatora snage sa funkcijama merenja kvaliteta električne energije tipska oznaka MM2 R

TehničkaPravila_552_usvojeno 2017 dopuna 2

Hioki Japan sa zadovoljstvom najavljuje lansiranje AC mernih kljesta CM3289, nova i poboljša sa tanjim senzorom je naslednik popularnog F. HIOK

WAMSTER Prezentacija

URED OVLAŠTENE ARHITEKTICE GLAVNI PROJEKT Investitor: OPĆINA KRŠAN ALEMKA RADOVIĆ GORIČANEC, dipl.ing.arh. - PROJEKT VODE I KANALIZACIJE - Br.elab. 56

VIKING GRIJANJE ako želite sustav grijanja vrhunske kvalitete i efikasnosti, niskih pogonskih troškova, bez dugotrajne, zahtjevne i skupe izvedbe, bez

INVESTITOR: OPĆINA TRPANJ, OIB: Kralja Tomislava 41, Trpanj UREĐENJE ZAPADNOG DIJELA PLAŽE "LUKA" k.č. 3448,2564, k.o. Trpanj

Element ventilatora ER 60 VZC , Upute za projektiranje

РЕПУБЛИКА СРБИЈА МИНИСТАРСТВО ПРИВРЕДЕ ДИРЕКЦИЈА ЗА МЕРЕ И ДРАГОЦЕНЕ МЕТАЛЕ Београд, Мике Аласа 14, ПП: 34, ПАК: телефон: (011)

NIAS Projekt e-građani KORISNIČKA UPUTA za aplikaciju NIAS Verzija 1.1 Zagreb, srpanj 2014.

SAŽETAK POZIVA Poziv na dostavu projektnih prijedloga Povećanje energetske učinkovitosti i korištenja obnovljivih izvora energije u uslužnom sektoru (

UNUTRANJI TRANSPORT I SKLADIŠTENJE

QSG CD640_645_Croatian_6pages_INTERNET_ qxd

Z-16-45

Z-16-48

job

E-RAČUN ZA POSLOVNE SUBJEKTE ZAPRIMANJE I SLANJE E-RAČUNA JE LAKO, PROVJERITE U FINI KAKO...

VRAČEVIĆ FRANJO.pdf

Normizacija - Nove norme u HZN TO 21

Seminar Novi zakonodavni okvir za elektroenergetski sektor

6. TEHNIČKE MJERE SIGURNOSTI U IZVEDBI ELEKTROENERGETSKIH VODOVA

Naziv naručitelja: RIJEKA plus d.o.o. Godina: 2019 Rbr Evidencijski broj Predmet nabave Brojčana oznaka nabave premeta nabave iz CPV-a Procijenjena vr

Microsoft Word - skladista

Microsoft Word Prilog potvrdi (proširenje, suženje..)-post. doku.(606374)

** Osnovni meni

Slide 1

Konstr

5

PowerPoint Presentation

Microsoft Word - GEMMA - FABER Inca LUX EG8 X A52_A70 Kuhinjska napa.doc

Kontrolna lista za obilazak radnog mjesta Stomatološki tehničar KONTROLNA LISTA ZA OBILAZAK RADNOG MJESTA Svrha obilaska radnog mjesta je utvrditi, uk

Niloé Proizvod po mjeri Elegantan dizajn

(Microsoft Word Transport plina sije\350anj I)

Uvod u proceduru sprovođenja energijskog audita

Z-18-61

РЕПУБЛИКА СРБИЈА МИНИСТАРСТВО ПРИВРЕДЕ ДИРЕКЦИЈА ЗА МЕРЕ И ДРАГОЦЕНЕ МЕТАЛЕ Београд, Мике Аласа 14, ПП: 34, ПАК: телефон: (011)

PRIKAZIVAČ BRZINE I BROJILO PROMETA ZA STATISTIČKU OBRADU PODATAKA

НАЗИВ ДОКУМЕНТА

Specifikacija usluga

Slide 1

Istraživanje i proizvodnja nafte i plina Sektor istraživanja Služba istraživanja stijena i fluida Transportni sustav Kromatografska analiza prirodnog

ACCUVAC Pro Vrhunsko iskustvo ono što stručnjaci zahtijevaju

Microsoft Word - VS_prospekt.docx

Logičke izjave i logičke funkcije

RIJEKA plus d.o.o. Godina: 2019 Rbr Evidencijski broj Predmet nabave Brojčana oznaka nabave premeta nabave iz CPV-a Procijenjena vrijednost nabave (u

M-3-643

Транскрипт:

TM NOVEC 1230 SUSTAVI ZA GAŠENJE POŽARA FM-200 SUSTAVI ZA GAŠENJE POŽARA www.apin.hr CJELOVITO PROTUPOŽARNO RJEŠENJE ZRAKONEPROPUSNOST ŠTIÆENOG PROSTORA DOOR FAN TEST/BLOWER DOOR DETEKCIJA UZORKOVANJEM ZRAKA PODTLAK / PRETLAK U ŠTIÆENOM PROSTORU KOD AKTIVIRANJA SUSTAVA SERVERI SA ZATVORENIM SUSTAVOM HLAÐENJA OneU SUSTAV Reliable. Optimal. Safe. Fire Solutions.

TM NOVEC 1230 / FM-200 PROTUPOŽARNI SUSTAVI ALARM SUSTAVA DETEKCIJE POŽARA UZORKOVANJEM ZRAKA Za hlaðenje server prostora u pravilu su predviðeni sustavi hlaðenja sa velikom brzinom strujanja zraka. Navedena brzina strujanja zraka za posljedicu ima izrazito negativan efekt na vrijeme potrebno da klasièni javljaèi požara uðu u alarm. Pravovremeni ulazak dimnih javljaèa požara u alarm osiguran je iskljuèivo uz uvjet iskljuèenja sustava hlaðenja. Iskljuèenje sustava hlaðenja predviða se na signal alarma sustava za detekciju požara uzorkovanjem zraka. Navedeni sustavi su izuzetno osjetljivi na pojavu dima. Maksimalno dozvoljeno vrijeme iskljuèenja hlaðenja server prostora obvezatno je potrebno definirati u dogovoru sa IT struènjacima da ne doðe do ošteãenja servera uslijed pregrijavanja. Nakon isteka maksimalno dozvoljenog vremena iskljuèenja hlaðenja obvezatno se sustav hlaðenja treba automatski ponovno ukljuèiti. PREDALARM VATRODOJAVNOG SUSTAVA Po ulasku u alarm jednog javljaèa požara (signal predalarma) nužno je proslijeðenje signala požara sa centrale gašenja na glavnu vatrodojavnu centralu. Ovlaštena osoba po primitku navedenog signala dužna je provjeriti u server prostoru dali je došlo do požara. ALARM VATRODOJAVNOG SUSTAVA Ukoliko je i drugi javljaè požara ušao u alarm potrebno je: kod zatvorenog sustava hlaðenja server prostora - ukljuèiti hlaðenje i iskljuèiti ventilaciju kod otvorenog sustava hlaðenja server prostora - iskljuèiti hlaðenje i iskljuèiti ventilaciju Strujanje zraka pomiješanog sa protupožarnim plinom pospješuje gašenje ukoliko je sustav hlaðenja izveden kao zatvoreni sustav. Ujedno se po alarmu požara sa centrale gašenja na vatrodojavnu centralu proslijeðuje signal požar koji za posljedicu ima izvršavanja postupaka u sluèaju požara na graðevini, te aktiviranje svjetlosno zvuène signalizacije. ODGODA GAŠENJA Centrala detekcije uzorkovanjem Alarm detekcije uzorkovanjem * toèno vrijeme treba definirati IT struènjak zbog moguænosti pregrijavanja servera Odgoda 2 min* Omoguæavanje prorade vatrodojavnog sustava (uslijed velike brzine strujanja zraka u server prostorima) VDC Alarm detekcije uzorkovanjem Elektro ormar ventilacije i klimatizacije Iskljuèenje sustava hlaðenja štiãenog prostora Elektro ormar ventilacije i klimatizacije Ukljuèenje sustava hlaðenja štiãenog prostora Plinovi Novec 1230 i FM-200 u projektiranim koncentracijama nisu štetni za zdravlje, ali zbog smanjene vidljivosti tijekom gašenja projektira se odgoda aktiviranja gašenja. Odgoda gašenja odnosno vrijeme predviðeno za evakuaciju osoblja zateèenog u server prostoru uobièajeno se projektira na 20 sekundi. Navedeno vrijeme odgode gašenja potrebno je korigirati ukoliko se radi o velikim server prostorima.

TM NOVEC 1230 / FM-200 PROTUPOŽARNI SUSTAVI OSIGURANJE ŠTIÆENOG PROSTORA OD OŠTEÆENJA USLIJED PODTLAKA/PRETLAKA Tijekom gašenja uslijed promjene agregatnog stanja plina na mlaznicama (tekuæina - plin) dolazi do hlaðenja štiæenog prostora. Uslijed toga dolazi do pojave podtlaka u štiæenom prostoru. Daljnjim tijekom gašenja poveæava se kolièina plina u štiæenom prostoru te dolazi do pojave pretlaka. Da bi se izbjeglo ošteæenje graðevinske konstrukcije zbog promjene tlakova postojeæi ventilacijski kanali se koriste za rastereæenje. Zbog navedenog je izuzetno bitno pravovremeno zatvaranje protupožarnih zaklopka. Zaklopke se trebaju zatvarati nakon maksimalnih pojava podtlaka / pretlaka u štiæenom prostoru. Predalarm požar Alarm požar Odgoda 20 s Odgoda 25 s Sustav klimatizacije Signalizacija predalarma na VDC Aktiviranje EM okidaèa na spremnicima Tlak u štiãenom prostoru (Pa) Otvoren sustav Zatvoren sustav Signalizacija alarma na VDC Aktiviranje svjetlosno zvuène signalizacije Tlak u štiãenom prostoru / Vrijeme Vrijeme (s) Elektro ormar pp zaklopki Zatvaranje pp zaklopki Elektro ormar ventilacije i klimatizacije Iskljuèenje ventilacije i klimatizacije štiãenog prostora Elektro ormar ventilacije i klimatizacije Ukljuèenje klimatizacije Iskljuèenje ventilacije Osiguranje integriteta štiæenog prostora Osiguranje koncentracije plina tijekom 10 min Signalizacija pada tlaka u spremniku

ISPITIVANJE ZRAKONEPROPUSNOSTI SERVER PROSTORA DOOR FAN TEST / BLOWER DOOR TEST ZRAKONEPROPUSNOST SERVER PROSTORA ISPITIVANJE ZRAKONEPROPUSNOSTI Kod aktiviranja protupožarnog sustava za zaštitu servera iznimno je bitno osigurati zadržavanje plina za gašenje u štiæenom prostoru u odgovarajuæoj koncentraciji. Time se osigurava kvalitetno gašenje požara. Normama prema kojima se projektiraju protupožarni sustavi za gašenje servera: norma ISO 14520 / EN 15004 ili norma NFPA 2001 zahtijevano je osiguranje minimalnog vremena zadržavanja plina u štiæenom prostoru. Da bi se osigurala odgovarajuæa zrakonepropusnost štiæenog prostora normama su definirani naèini ispitivanja zrakonepropusnosti kao i kriteriji koje štiæeni prostori trebaju zadovoljiti. Navedena zrakonepropusnost se sukladno normama treba provjeravati kod prvog ispitivanja sustava i svake godine jednom godišnje kod redovnog ispitivanja stabilnog sustava za gašenje požara. EN 15004 - Chapter 7.8. Duration of Protection 7.8.1 It is important that an effective extinguishant concentration not only be achieved, but is maintained for a sufficient period of time to allow effective emergency action.... 7.8.2 It is essential to determine the likely period during which the extinguishing concentration will be maintained within the protected enclosure. This is known as the hold time. The predicted hold time shall be determined by the door fan test specified in Annex E, or a full discharge test based on the following criteria: a) at the start of the hold time, the concentration throughout the enclosure shall be the design concentration; b) at the end of the hold time, the extinguishant concentration at 10 %, 50 % and 90 % of the enclosure height shall be not less than 85 % of the design concentration; c) the hold time shall be not less than 10 min, unless otherwise specified by the authority.... MINIMALNO VRIJEME ZADRŽAVANJA PLINA U ŠTIÆENOM PROSTORU Normama ISO 14520 (EN 15004) i NFPA 2001 propisani su zahtjevi za minimalnim vremenom zadržavanja koncentracije plina u štiæenom prostoru. Navedeno minimalno vrijeme zadržavanja plina u štiæenom prostoru moguæe je provjeriti na dva naèina: ispucavanjem plina u štiæeni prostor i mjerenjem koncentracije plina tijekom 10 minuta ili provedbom door fan testa (ISO 14520 - Annex E / NFPA 2001 - Annex C) Door fan test se provodi pomoæu specijalnog ureðaja "blower door" koji se sastoji od ventilatora, mjerne opreme i softwarske podrške. U štiæenom prostoru se pomoæu ventilatora radi pretlak, te potom podtlak. Specijalnom mjernom opremom provode se oèitanja kojom se dobivaju izlazni podaci sukladni EN 13829 normi. Izlazni podaci mjerenja unose se u software koji provodi izraèun sukladan normama ISO 14520 (EN 15004) i NFPA 2001. Konaèan izlazni rezultat je vrijeme zadržavanja plina u štiæenom prostoru. Ukoliko vrijeme zadržavanja plina nije sukladno normama tada se anemometrom utvrðuju zone propuštanja koje se brtve, te se door fan test provodi ponovno. Ispitivanje zrakonepropusnosti štiæenog prostora je obavezan i sastavni dio ispitivanja funkcionalnosti sustava za gašenje požara plinovima (FM-200, Novec 1230, Inergen,...) propisanog èlankom 40. Zakona o zaštiti od požara. NFPA 2001 Chapter 5.6 Duration of Protection A minimum concentration of 85 percent of the adjusted minimum design concentration shall be held at the highest level of combustibles for a minimum period of 10 minutes or for a time period to allow for response by trained personnel. 5.6.1* It is important that the adjusted minimum design concentration of agent not only shall be achieved but also shall be maintained for the specified period of time to allow effective emergency action by trained personnel. SEKUNDARNI DOBITAK ZA INVESTITORA Ispitivanjem zrakonepropusnosti i odgovarajuæim brtvljenjima ovojnice štiæenog prostora znaèajno se smanjuje gubitak zraka iz server prostora, te se poboljšava energetska uèinkovitost sustava za hlaðenje èime se ostvarajuje znaèajna ušteda energije. DOOR FAN TEST / BLOWER DOOR Djelatnici APIN sustava posjeduju certifikate o obuci i u moguænosti su provesti ispitivanje zrakonepropusnosti.

AIR SAMPLING SYSTEM DETEKCIJA POŽARA UZORKOVANJEM ZRAKA VESDA SUSTAV DETEKCIJE POŽARA UZORKOVANJEM ZRAKA Xtralis Vesda sustav osigurava najraniju moguãu detekciju požara dajuãi više nivoa alarma kod razvoja požara. Navedenim naèinom detekcije omoguãena je pravovremena akcija u server prostoru da bi se izbjegla šteta. Kod zaštite server prostora "èistim" plinovima Vesda sustav omoguãuje vrlo brzu detekciju dima što za posljedicu ima iskljuèenje sustava hlaðenja èime se omoguãava vatrodojavi da uðe u alarm i aktivira sustav gašenja. Dijagram prikazuje razvoj požara tijekom vremena. Evidentno je da sustav Vesda omoguæuje vrlo ranu detekciju požara. Ujedno prema zahtjevu korisnika moguæe je konfigurirati sustav na višestruke nivoe alarma u ovisnosti prema kolièini dima koji se pojavljuje u štiæenom prostoru. NAÈIN RADA VESDA SUSTAVA Princip rada Vesda sustava je kontinuirano usisavanje zraka u cjevovod detekcije uzorkovanja pomoãu visoko uèinkovitog aspiracijskog sustava. Zrak prolazi kroz filter sa dvije razine. Na prvoj razini filter èisti izuzeti zrak od prašine i neèistoãa prije nego što uðe u lasersku komoru. Druga razina filtera osigurava vrlo èisti zrak koji garantira èistoãu površine optike što za posljedicu ima sigurnu i kvalitetnu kalibraciju sustava i dugi vijek funkcioniranja sustava. Nakon filtera zrak ulazi u komoru gdje prolazi kroz laserski svjetlosni snop. Kada se u zraku nalazi dim dolazi do narušavanja oèitanja što se odmah detektira u vrlo osjetljivom prihvatnom modulu detekcije. PRIMJENA VESDA SUSTAVA Signal o pojavi dima se proslijeðuje i prikazuje na više linijskom grafikonu, indikatoru najveæege moguæeg alarma i/ili grafièkom display-u. Vesda centrala je u moguænosti proslijediti signale na vatrodojavnu centralu ili centralni nadzorni sustav. U tehnološkim procesima gdje je izuzetno bitna pouzdanost i gdje ispadanje tehnološkog sustava predstavlja veliku štetu najranija detekcija požara omoguãuje brzu i pravovremenu akciju (telekomunikacijski prostori, financijski data centri, server prostori, èisti prostori,...) U prostorima gdje zrak vrlo brzo struji te se zasiãenost dima u prostoru ne koncentrira u najvišim dijelovima veã se jednoliko rasporeðuje po cijelom prostoru U prostorima gdje je otežano održavanje i ispitivanje sustava vatrodojave (spušteni stropovi, kompjuterski podovi, okna liftova, proizvodni pogoni, kanali, zatvor,...) U prostorima gdje je nepoželjna vidljivost klasiènog javljaèa požara zbog estetskih razloga ili zbog vandalizma U prostorima gdje se zahtijeva brza evakuaciju ljudi u sluèaju požara U prostorima koji imaju zahtjevne pogonske uvjete (hladnjaèe, javni prijevoz, proizvodni pogoni, elektrane, automatski pogoni,...) U prostorima zaštiãenim sustavima za gašenje požara "èistim" plinovima Vesda omoguãuje pravoremeno upravljanje sustavom hlaðenja (komunikacijska èvorišta, server prostori, upravljaèke stanice,...) DETEKCIJA POŽARA UZORKOVANJEM ZRAKA

PODTLAK / PRETLAK KOD AKTIVIRANJA GAŠENJA OSIGURANJE ŠTIÆENOG PROSTORA OD OŠTEÆENJA PODTLAK / PRETLAK KOD AKTIVIRANJA GAŠENJA OPÆENITO Izuzetno je bitno uoèiti da kod gašenja požara èistim plinovima postoje u principu dva razlièita modela poveãanja tlaka u štiãenom prostoru. Kod sustava za gašenje požara inertnim plinovima dolazi do znaèajne pojave pretlaka tijekom gašenja uslijed znaèajnog poveãanja volumena plinova u štiãenom prostoru. Zbog navedenog je potrebno obavezno predvidjeti žaluzine za rastereãenje tlaka kod aktiviranja sustava. Kod gašenja požara plinovima FM-200 i Novec 1230 kao i kod gašenja požara drugim halokarbonskim plinovima u prvom dijelu istjecanja plina dolazi do pada tlaka u štiãenom prostoru nakon èega slijedi porast tlaka. Izuzetno je bitno da maksimalne vrijednosti podtlaka i pretlaka u štiãenom prostoru ne izazovu ošteãenja graðevinske konstrukcije štiãenog prostora. Ukoliko doðe do ošteãenja graðevinske konstrukcije (spušteni stropovi, zidovi, vrata, prozori,...) više sustav za gašenje požara nije u moguãnosti osigurati potrebnu koncentraciju za gašenje požara. PROMJENE TLAKA KOD GAŠENJA PLINOVIMA FM-200 / Novec 1230 Kod gašenja plinovima FM-200 / Novec 1230 pad tlaka u štiãenom prostoru pojavljuje se zbog hlaðenja koje se javlja uslijed utroška energije kod promjene agregatnog stanja na mlaznici (tekuãa faza prelazi u plinsku). Tlak u štiæenom prostoru (Pa) Tlak u štiæenom prostoru / Vrijeme Vrijeme (s) Porast tlaka u štiãenom prostoru koji se javlja nakon pada tlaka posljedica je poveãanja kolièine plina uslijed gašenja u štiãenom prostoru. Krivulja pada i porasta tlaka u štiãenom prostoru ovisna je o plinu koji se koristi za gašenje požara. Priloženi dijagram prikazuje razlike u podtlaku/ pretlaku tijekom gašenja za razlièite vrste èistih plinova kod gašenja identiènog prostora i pod jednakim uvjetima. GRANIÈNE VRIJEDNOSTI PODTLAKA / PRETLAKA ZA ŠTIÆENE PROSTORE Izuzetno je bitno poznavati maksimalne vrijednosti dozvoljenog podtlaka i pretlaka u štiãenom prostoru za razlièitu vrstu gradnje i razlièitu uporabu materijala štiãenog prostora. Uobièajene dozvoljene maksimalne vrijednosti podtlaka / pretlaka za pojedine prostore su: prostori sa staklenim prozorima 100 Pa prostori sa knauf zidovima/stropovima 300 Pa prostori napravljeni èvrstom gradnjom 500 Pa Izraèun maksimalne vrijednosti podtlaka/ pretlaka izuzetno je složen i zahtjevan buduæi da je ovisan o cijelom nizu ulaznih podataka. Izuzetno bitni podatci za potvrdu izraèuna pojave moguæih podtlaka/pretlaka u štiæenom prostoru su podaci dobiveni door fan test - om gdje je izlazni podatak ekvivalentna površina svih otvora na štiæenom prostoru. Navedeni podatak je jedan od ulaznih podataka za konaènu provjeru maksimalnog podtlaka koji se može pojaviti u štiæenom prostoru. JEDNOSTAVAN NAÈIN RJEŠENJA PODTLAKA/PRETLAKA KOD GAŠENJA Pitanje pojave podtlaka/pretlaka u štiãenom prostoru najjednostavnije se rješava uporabom ventilacije štiãenog prostora. Pravovremenim aktiviranjem protupožarnih zaklopki dozvoljava se rastereãenje štiãenog prostora kroz ventilo kanale. Ukoliko se projektira navedeni model izuzetno je bitno kod koordinacije sustava ventilacije i protupožarnog sustava sagledati vremena zatvaranja protupožarnih zaklopki, vrijeme odgode gašenja, te vrijeme trajanja ispucavanja plina.

SERVERI SA ZATVORENIM SUSTAVOM HLAÐENJA OneU sustav gašenja FUNKCIJA Sustav za gašenje požara OneU specijalni je sustav za detekciju i gašenje požara elektro ormara sa zatvorenim sustavom hlaðenja. OneU sustav koncipiran je za jednostavnu ugradnju, te siguran i pouzdan rad. OPIS RADA SUSTAVA Širina 19" x Visina 44 mm x Dubina 620 mm Integrirani sustav detekcije požara uzorkovanjem zraka nadzire eventualnu pojavu dima u zraku koji se konstantno uzima iz switch ormara pomoãu cjevovoda detekcije uzorkovanjem koji je trajno ugraðen u štiãenom ormaru. Uobièajeno je razina osjetljivosti detekcije požara uzorkovanjem u navedenim sustavima predviðena kao jako osjetljive i normalno osjetljive razine. Ovim naèinom su osigurana dva nivoa oèitanja èime je moguãe predvidjeti razlièite kombinacije iskljuèenja i upravljanja štiãenim sustavom. Kod detekcije požara dolazi do ispuštanja plina Novec 1230 koji je trajno pohranjen u spremniku sustava i raspršivanja istog na mlaznici. Specijalna geometrija mlaznice osigurava da plin u cjelosti ispari na samoj mlaznici. Sigurnosnim napajanjem predviðenim u sklopu same OneU jedinice osiguran je besprekidan rad sustava u trajanju 4 sata. Radom sustava moguãe je jednostavno nadzirati i upravljati preko LCD display-a i dodatnih LED lampica. Ujedno su predviðeni i kontakti za proslijeðenje signala kvara i alarma na vatrodojavni sustav ili centralni nadzorni sustav. Dodatna opcija je moguãnost ugradnje zvuèno svjetlosne signalizacije prorade sustava. IZVEDBE SUSTAVA One U sustav SASTAVNI DIJELOVI 1 Spremnik plina Novec 1230 sa nadzorom propuštanja i mlaznicom za gašenje 2 Vrlo osjetljiv sustav detekcije požara uzorkovanjem 3 Napajanje sustava 4 Baterije OneU sustav sadrži sustav detekcije požara i sustav gašenja integriran u jednu jedinstvenu cjelinu 19" standardne switch komponente. Sustav je adekvatan za zaštitu switch ormara 3 volumena do 3 m. OneU DD sustav OneU DD sustav sadrži sustav detekcije požara u formi 19" standardne switch komponente. Ovim sustavom moguæe je nadzirati ukupno èetiri switch ormara preko cjevovoda detekcije uzorkovanjem. OneU ED sustav OneU ED sustav sadrži sustav za gašenje požara u formi 19" standardne switch komponente. 3 Sustav je adekvatan za zaštitu switch ormara sa volumenom do 3 m. OneU ED sustav u cjelosti je kompatibilan sa OneU DD sustavom za detekciju požara. Na navedeni sustav moguæe je spojiti i nadzirati ukupno èetiri OneU ED jedinica. PODRUÈJE PRIMJENE OneU sustav se ugraðuje u standardne 19" elektro ormare sa vlastitim hlaðenjem gdje je zahtijevan visoki nivo pouzdanosti rada sustava (IT, server, mrežne tehnologije, upravljanje proizvodnjom,...) SERVERI SA ZATVORENIM SUSTAVOM HLAÐENJA

CJELOVITA RJEŠENJA PROTUPOŽARNE ZAŠTITE PROJEKTNA RJEŠENJA: UGRADNJA I SERVIS: PIN PIN Automatske Protupožarne INstalacije Automatske Protupožarne INstalacije APIN PROJEKT d.o.o. APIN SUSTAVI d.o.o. za projektiranje, gradnju i trgovinu za projektiranje, gradnju i trgovinu OIB 03073221751 Žiro raèun: PBZ 2340009-1110309292 OIB 22659472331 Žiro raèun: PBZ 2340009-1110308982 Adresa: Adresa: Ožujska 8 HR-10000 Zagreb Hrvatska Ožujska 8 HR-10000 Zagreb Hrvatska Kontakt podaci: Kontakt podaci: Tel. +385 1 38 70 528 Fax. +385 1 38 70 529 Tel. +385 1 38 70 520 Fax. +385 1 38 70 521 www.apin.hr www.apin.hr www.apin.hr Reliable. Optimal. Safe. Fire Solutions.